Find the user manual and the help you need for the products you own at ManualsOnline. To locate your free Heath Zenith manual, choose a product type below. Showing Product Types 1 - 15 of 15. × Sign Up for ManualsOnline Login with Facebook.
Advertising
Heath Zenith 5316-a User Manual
Get Heath Zenith DualBrite Replacement Sensor Head SH-5316 DualBrite Replacement Sensor Head Owner's Manual. Get all Heath Zenith manuals! Owner's Manuals. Looking for an owner's manual for your product? Enter your model number below.
4
598-1153-02
POSSIBLE CAUSE
1. A bulb is positioned too close to the
1. A bulb is positioned too close to the
sensor or pointed at nearby objects
that cause heat to trigger the sensor.
(Reposition the bulb away from the
sensor or nearby objects).
that cause heat to trigger the sensor.
(Reposition the bulb away from the
sensor or nearby objects).
2. Sensor is pointed toward a heat source
like an air vent, dryer vent, or brightly-
painted heat-reflective surface. (Repo-
sition sensor. Reduce RANGE).
painted heat-reflective surface. (Repo-
sition sensor. Reduce RANGE).
3. Light control is in Manual Mode. (Switch
to Auto).
1. Heat or light from the bulbs may be
turning the light control on and off.
(Reposition the bulbs away from the
sensor).
(Reposition the bulbs away from the
sensor).
2. Heat being reflected from other objects
may be affecting the sensor. (Reposi-
tion sensor).
tion sensor).
3. Light control is in the TEST mode and
warming up. (Flashing is normal under
these conditions. Turn BOOST off).
these conditions. Turn BOOST off).
1. Sensor is detecting its own lights.
(Reposition bulbs to keep area below
the sensor relatively dark).
the sensor relatively dark).
SYMPTOM
Lights stay
on continu-
ously.
Lights stay
on continu-
ously.
Lights flash
on and off.
on and off.
Lights flash
once, then
stay off in
Manual Mode.
once, then
stay off in
Manual Mode.
SYMPTOM
Lights will
not come on.
Lights will
not come on.
Lights come
on in day-
light.
on in day-
light.
Lights come
on for no
apparent
reason.
on for no
apparent
reason.
Lights turn
off too late
in Dusk-to-
Dawn setting.
off too late
in Dusk-to-
Dawn setting.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Light is loose or burned out.
3. Fuse is blown or circuit breaker is
1. Light switch is turned off.
2. Light is loose or burned out.
3. Fuse is blown or circuit breaker is
turned off.
4. Daylight turn-off is in effect (Recheck
after dark).
5. Incorrect circuit wiring, if this is a new
installation.
6. Re-aim the sensor to cover desired
area.
1. Light control may be installed in a
relatively dark location.
2. Light control is in TEST. (Set control
switch to an ON-TIME position).
1. Light control may be sensing small
animals or automobile traffic. (Re-aim
sensor).
sensor).
2. RANGE is set too high. (Reduce
RANGE).
3. D
ual
B
rite
®
Timer is on.
1. Sensor is in a relatively dark location.
(Relocate sensor, or use 3 hr or 6 hr
setting).
setting).
TROUBLESHOOTING GUIDE
Advertising
Popular Brands
Popular manuals
Advertising
Features
• D
ual
Z
one
™ Technology.
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Bulb Saver™ - Extends bulb life by up to 4x standard
• Automatically turns lighting off.
• Bulb Saver™ - Extends bulb life by up to 4x standard
bulbs. Lights bulb to full bright in under 2 seconds.
• Patented D
ual
B
rite
®
Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
• LED indicates motion was sensed (day or night).
Requirements
• Not for use with fluorescent lights.
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must
be wired through a switch.
•
Install sensor in accordance with local codes.
© 2008 HeathCo LLC
598-1153-02
OPERATION
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
TEST
TEST 1 5 20
ON-TIME
Off 3 6 Dusk to
Dawn
Put ON-TIME switch
on the sensor bottom
to TEST and the D
on the sensor bottom
to TEST and the D
ual
-
B
rite
®
switch OFF.
D
ual
B
rite
®
Timer
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or 20
minutes) then returns to dim mode.
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or 20
minutes) then returns to dim mode.
MANUAL MODE
ON-TIME
TEST
1 5 20
... back on.
AUTO
1 Second OFF
then...
Move ON-TIME Switch to
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
bration time the control will be in the AUTO mode.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
ON-TIME switch in the 1, 5, or 20
position.
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
or 20 minute position.
Mode:
On-Time
Works:
Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
D
ual
B
rite
®
Replacement
Sensor Head
D
ual
B
rite
®
Model SH-5316
Advertising